Mecer Inverter 2400VA (1440W) Inverter Battery Charger (UPS) – Intelligent Fan 24V

R3999,00

Mecer Inverter 2400VA (1440W) Inverter Battery Charger (UPS) – Intelligent Fan 24V

Category: Tag:

Description

Description

Please note that this unit will not turn on if not connected to at least two 12V batteries connected in series for 24V.
The fan will turn off once batteries are fully charged!

Optional Solar Charge Controller

Mecer 2400VA, 1400W, 24V DC-AC Inverter. (Modified Sine Wave)

Cables to connect the unit to a battery are included.

A 220V power cable is included to recharge the battery while the power is on.

May be used as an inverter (to power 220V devices such as TVs from a battery) or

a UPS (runs the device from the standard 220V power while the battery charges)

Not designed to run in a DB Board

External Battery Required
Features:
– Simulated sine wave inverter
– Built-in AVR for voltage regulation
– Wide input voltage range: 90-280 VAC
– 24VDC
– Overload and short circuit protection
– LCD display for comprehensive information

Specifications:
– Model: Mecer IVR-1200LBK
– Capacity: 2400 VA / 1440 W
– Power Factor: 0.6
– Input Voltage range 90-280VAC

Line Mode:
– Output Voltage
– Bypass mode: 0utput voltage same as input voltage
– AVR mode:Output voltage = Input voltage 1.2 at Input voltage – Output Frequency Same as input

Battery Mode:
– Output Voltage 230Vac +/-10%
– Transfer Time 20ms typical
– Waveform Modified Sine-wave

Overload Capability:
– Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault
– Load >130% +/-15%, fault immediately.
– AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode
– AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode
– Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately.

Short Circuit Protection:
– Line Mode Breaker
– Battery Mode Current limit +Firmware Protection

Battery:
– Battery Voltage 24 VDC
– Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery
– Polarity Reserve Protection Yes
– Charger available I/P range 90~280V
– Battery’s Not Included

Charger:
– Constant Current Charger Voltage 28.6VDC +/-2%
– Floating Charge Voltage 27.4VDC +/-2%
– Maximum Charge Current 10A or 20A
– DC Start Voltage >22VDC

Physical:
– Dimension, D X W X H (mm) 350 x 90 x 300
– Net Weight (kgs) 5.5

Environment:
– Operating Humidity 0 to 90% Relative Humidity(Non-condensing)
– Operating Temperature 0 degrees C to 40 degrees C
– Storage Temperature -15 degrees C to 50 degrees C